Identification
- Manufacturer / reference
- Märklin 60832
- Gauge / scale
- No scale
💥 Gran stock en vías, desvíos y tramos flexibles: ¡ahorra al menos un 50 %!
Märklin 60832 – m83 decoder is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Technical data, history and available documents for this model.
Ventajas exclusivas al comprar con nosotros:
Mainland Spain: standard shipping €4.99 below €69; free standard shipping from €69. Items from our own warehouse are dispatched once a week, normally Wednesday or Thursday.
Priority MRW: €9.99 below €69; €7.99 from €69. Paid, available goods ready in our warehouse: orders received before 10:00 mainland Spanish time are handed to MRW the same working day, otherwise by the next working day. Weekends and public holidays excluded. Estimated transit: 24–48 working hours after handover to MRW, not after ordering.
Balearic Islands: minimum goods value €75 + €10 shipping. No free shipping or priority MRW. Goods thresholds are after discounts and exclude shipping.
Tracked shipping. Pre-orders, special-order goods and external warehouse items retain their availability lead times; MRW does not make them immediately available. Full terms and other destinations.
Manufacturer information describes the model. The item description and photos define the condition and contents of this particular offer.
Märklin 60832 m83 for switching turnouts, signals and uncoupler tracks; eight outputs controlled separately or in pairs. Factory setting for up to four turnouts.
The product page specifies Motorola addresses up to 320 and DCC up to 2040, set by coding switches or programming track in groups of four. Stated maximum total load: 3 A. Lift-type screw terminals.
mfx is used for registration and configuration; switching still operates under MM or DCC. mfx registration requires Central Station 60215 or higher. Switch 10: OFF for MM, ON for DCC. After mfx registration, configuration uses mfx rather than MM parameters/DCC CVs.
Power from track or 66360 only together with 60822. Connect m83/m84 directly: no extension cables between side contacts and no additional track connection. Motor drives require one 60821 per output pair.
Disconnect all power before wiring or changing switches. Do not open the housing; dry indoor use only. Strip and twist wire ends without tinning before clamping.
CV79: mode 0, four turnouts/4 addresses; 1, eight momentary switches/4 addresses without status display; 2, eight switches/8 addresses; 3, blinking and random/8 addresses; 4, fluorescent street lighting/8 addresses; 5, energy-saving lighting/8 addresses.
Output configuration uses CV112–135; pulse width and period are separate settings. Recommended for C turnouts: 30% and 0.25 s; K/M: 75% and 0.5 s. Configure via mfx after mfx registration.
The 2026 lighting supplement requires shunt resistors and correct polarity for LED lights 72800/72804/72809 as shown in its wiring diagram. The 19 V, maximum 200 mA incandescent-lamp example is not a universal direct LED connection approval.
The original DCC and mfx table retains unusable rows and empty values. These are mode values, not F keys. The repeated value 138 for Gyro Light is retained from the source and remains unresolved. Spanish mode 8 is clarified as light fade in/out using DE/EN.
The pictogram specifies adults only; the product warning block also mentions children under three. Check the actual offer for the example’s condition and accessories.
| Button | Switch | Designation | Remarks |
|---|---|---|---|
| 0 | 128 | Everything Off | |
| 1 | 129 | Dimmer | |
| 2 | 130 | Blinking Light 1 | |
| 3 | 131 | Blinking Light 2 | Inverse blinking light to Blinking Light 1 |
| 4 | 132 | Flash 1 | Flashing light |
| 5 | 133 | Flash 2 | Double flashing light |
| 6 | 134 | Random Display / Light Flickering | Random sequence of pause/pulse |
| 8 | 136 | Light fade in/out | Soft on/off action |
| 9 | 137 | Mars Light | Defined blinking light |
| 10 | 138 | Gyro Light | Defined blinking light |
| — | — | Light according to Rule ... | Cannot be used |
| — | — | Light according to Rule ... | Cannot be used |
| 13 | 141 | Neon Lights | Simulates fluorescent lights |
| 14 | 142 | Energy-Saving Light | Simulates energy-saving lights |
| 15 | 143 | Uncoupler Track | |
| 16 | — | Switching | "Period" indicates the max. switching duration |
| 17 | — | Min. Switching | "Period" indicates the min. switching duration |
| 18 | — | Sensor Switching | Switching duration is "Period" or until end shutoff position is reached |
| Turn On | Cannot be used |
Märklin 60832
Märklin 60832 m83 for switching turnouts, signals and uncoupler tracks; eight outputs controlled separately or in pairs. Factory setting for up to four turnouts.
The product page specifies Motorola addresses up to 320 and DCC up to 2040, set by coding switches or programming track in groups of four. Stated maximum total load: 3 A. Lift-type screw terminals.
mfx is used for registration and configuration; switching still operates under MM or DCC. mfx registration requires Central Station 60215 or higher. Switch 10: OFF for MM, ON for DCC. After mfx registration, configuration uses mfx rather than MM parameters/DCC CVs.
Power from track or 66360 only together with 60822. Connect m83/m84 directly: no extension cables between side contacts and no additional track connection. Motor drives require one 60821 per output pair.
Disconnect all power before wiring or changing switches. Do not open the housing; dry indoor use only. Strip and twist wire ends without tinning before clamping.
CV79: mode 0, four turnouts/4 addresses; 1, eight momentary switches/4 addresses without status display; 2, eight switches/8 addresses; 3, blinking and random/8 addresses; 4, fluorescent street lighting/8 addresses; 5, energy-saving lighting/8 addresses.
Output configuration uses CV112–135; pulse width and period are separate settings. Recommended for C turnouts: 30% and 0.25 s; K/M: 75% and 0.5 s. Configure via mfx after mfx registration.
The 2026 lighting supplement requires shunt resistors and correct polarity for LED lights 72800/72804/72809 as shown in its wiring diagram. The 19 V, maximum 200 mA incandescent-lamp example is not a universal direct LED connection approval.
The original DCC and mfx table retains unusable rows and empty values. These are mode values, not F keys. The repeated value 138 for Gyro Light is retained from the source and remains unresolved. Spanish mode 8 is clarified as light fade in/out using DE/EN.
The pictogram specifies adults only; the product warning block also mentions children under three. Check the actual offer for the example’s condition and accessories.
| Button | Switch | Designation | Remarks |
|---|---|---|---|
| 0 | 128 | Everything Off | |
| 1 | 129 | Dimmer | |
| 2 | 130 | Blinking Light 1 | |
| 3 | 131 | Blinking Light 2 | Inverse blinking light to Blinking Light 1 |
| 4 | 132 | Flash 1 | Flashing light |
| 5 | 133 | Flash 2 | Double flashing light |
| 6 | 134 | Random Display / Light Flickering | Random sequence of pause/pulse |
| 8 | 136 | Light fade in/out | Soft on/off action |
| 9 | 137 | Mars Light | Defined blinking light |
| 10 | 138 | Gyro Light | Defined blinking light |
| — | — | Light according to Rule ... | Cannot be used |
| — | — | Light according to Rule ... | Cannot be used |
| 13 | 141 | Neon Lights | Simulates fluorescent lights |
| 14 | 142 | Energy-Saving Light | Simulates energy-saving lights |
| 15 | 143 | Uncoupler Track | |
| 16 | — | Switching | "Period" indicates the max. switching duration |
| 17 | — | Min. Switching | "Period" indicates the min. switching duration |
| 18 | — | Sensor Switching | Switching duration is "Period" or until end shutoff position is reached |
| Turn On | Cannot be used |
Märklin 60832
Formas de pago